Job Admin Home
New Order
New Charger Order
New Charger Batch
OrderID: Customer Number: Order Status: Device Type: Manufacturer: Model Number: Serial Number: Service: Engineer: Date In: ETA: Completion Date: Problem Description: unable to control the speed by current reference Repair Actions: Computer control card has been cleaned, rebuilt and tested. Analog operational amplifiers have been replaced. Switching power supply board has been rebuilt. All output voltages tested OK. Drive was configured in V/F mode and tested OK at light load. All parameters were restored to original values. Final test passed. Comments:
OrderID:
Device Type: Manufacturer: Model Number: Serial Number:
Service:
Engineer: Date In: ETA: Completion Date:
Problem Description: unable to control the speed by current reference
Repair Actions:
Computer control card has been cleaned, rebuilt and tested. Analog operational amplifiers have been replaced. Switching power supply board has been rebuilt. All output voltages tested OK. Drive was configured in V/F mode and tested OK at light load. All parameters were restored to original values. Final test passed. Comments:
© Copyright ServoTech Electronics A3-26 Elm Street, Kitchener, Ontario, N2G 2G4 Tel: 519-342-6641 ■ Fax: 1-866-866-9424