Job Admin Home
New Order
New Charger Order
New Charger Batch
OrderID: Customer Number: Order Status: Device Type: Manufacturer: Model Number: Serial Number: Service: Engineer: Date In: ETA: Completion Date: Problem Description: incoming power fuses blown Repair Actions: replacement or repair of the drive Comments: Upon visual inspection of the drive, some traces of blown parts were detected. The internal right side of the drive has traces of smoke, explosion debris was present. We suspect W-phase output power module is damaged. Motor checked OK. Since other electrical machines in the plant were not affected we suspect an internal failure of this inverter. Air filters of the electrical cabinet were present and fairly clean. No signs of overcurrent were present on the power lines or drive terminals.
OrderID:
Device Type: Manufacturer: Model Number: Serial Number:
Service:
Engineer: Date In: ETA: Completion Date:
Problem Description: incoming power fuses blown
Repair Actions:
replacement or repair of the drive Comments:
Upon visual inspection of the drive, some traces of blown parts were detected. The internal right side of the drive has traces of smoke, explosion debris was present. We suspect W-phase output power module is damaged. Motor checked OK. Since other electrical machines in the plant were not affected we suspect an internal failure of this inverter. Air filters of the electrical cabinet were present and fairly clean. No signs of overcurrent were present on the power lines or drive terminals.
© Copyright ServoTech Electronics A3-26 Elm Street, Kitchener, Ontario, N2G 2G4 Tel: 519-342-6641 ■ Fax: 1-866-866-9424